If you have difficulty in submitting comments on draft standards you can use a commenting template and email it to admin.start@bsigroup.com. The commenting template can be found here.
This document describes a method for measuring adhesion strength between microcircuits and substrates by scratching with the wedged-shape diamond stylus. Using the traditional adhesion test, it is difficult to evaluate the adhesion strength of the microcircuits with a narrower scratching stylus.
During the test, applying stylus force is constant or progressive and normal to the surface. This yields adhesive and/or cohesive failures of the microcircuit coating-substrate system.
This test method is suitable for evaluating copper microcircuits up to a width of tens of micrometres. It is also applicable for evaluating fine patterns of other widths and materials. Forces in the range of 0,1 N to 30 N are used in this document. Although the proposed procedure may apply to other force ranges, an appropriate calibration is required to quantify the normal forces at which failures occur.
You are now following this standard. Weekly digest emails will be sent to update you on the following activities:
You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.
You have successfully unsubscribed from weekly updates for this standard.
Comment on proposal
Required form fields are indicated by an asterisk (*) character.