We use cookies to give you the best experience and to help improve our website

Find out what cookies we use and how to disable them

DDC 3-2023 NWI EN 12543-6 new standard Non-destructive testing — Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing — Part 6: Measurement of the effective focal spot size of micro- and nanofocus X-ray tubes with spot sizes < 100 µm

Scope

This European standard specifies a method for the measurement of effective focal spot dimensions between 0,2 µm and 100 µm of X-ray tubes up to and including 225 kV tube voltage by means of the line group fit method and evaluation of digital images.

The imaging quality and the resolution of X-ray images depend highly on the characteristics of the effective focal spot, in particular the size and the two-dimensional intensity distribution as seen from the detector plane.

This test method provides instructions for determining the effective size (dimensions) of nano and micro focal spots of industrial X-ray tubes. This determination is based on the evaluation of an X-ray image taken with line group gauges.

Purpose

In order to cover the full range of effective focal spot sizes, three different methods are described in EN 12543-2: 2021, EN 12543-4: 1999, and EN 12543-5: 1999 , which are actively used. The measurement method of EN 12543-2 is intended for effective focal spot dimensions above 0,1 mm of X-ray systems up to and including 1000 kV tube voltage by means of the pinhole camera method with digital evaluation. The edge method of EN 12543-4: 1999 is intended for effective focal spot sizes of macrofocus tubes with spot sizes of Y> 0,5 and up to 500 kV. The edge measurement method of EN 12543-5 is intended for measurement of effective focal spot sizes between 5µm and 300µm and mainly applicable for the use with microfocus tubes. During the last 10 years a new generation of X-ray tubes was developed with focal spot sizes < 5 µm down to 200 nm. This range is not covered by any international standard. New test gauges and procedures were developed in an European project to cover this range with sufficient measurement methods. An international Round Robin Test was conducted to evaluate and verify the new gauges and procedures. The concept of these measurement procedures permits covering a focal spot in the range from 0,2 µm to 100 µm. Note: in case the WI is based on documents from other organizations than ISO/IEC, please specify it here: -- No documents available in ISO/IEC. But the revision should be developed together with ISO TC 135 SC 5.

Comment on proposal

Required form fields are indicated by an asterisk (*) character.


Please email further comments to: debbie.stead@bsigroup.com

Follow standard

You are now following this standard. Weekly digest emails will be sent to update you on the following activities:

You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.

Unfollow standard

You have successfully unsubscribed from weekly updates for this standard.

Error