BS EN 50726-3 Emergency and danger systems. Part 3: Emergency and danger response systems (EDRS) - Risk management file and examples for applications

Source:
CENELEC
Committee:
GW/1/1 - Alarm components
Categories:
Alarm and warning systems
Comment period start date:
Comment period end date:
Number of comments:
0

Comment by:

Scope

This document specifies the structure, construction, content and sequence of a technical risk management process and the technical risk management file in accordance with EN 50726-1. It also describes application examples for technical risk management according to EN 50726-1.

An emergency and danger response system (EDRS) is used to minimize risks to life and limb. Its purpose is to report, verify and manage emergencies and dangers in order to prevent or limit personal injury.

As already mentioned in the scope of application of EN 50726-1, the implementation of the Occupational Safety and Health Act and the subsequent regulations is intended in order to take particular account of the protection objective defined therein (physical integrity). However, this not only includes a risk assessment (e.g. prevention of acts of violence) for employees, but also for everyone in the property.

The requirements of the Occupational Safety and Health Act are therefore intended to be observed when creating a safety concept and as part of the technical risk management process. Consequently, particular attention is drawn to paragraphs 5, 6 and 9 of the Occupational Safety and Health Act.

Risks to life and limb can include emergencies and dangerous situations that can cause psychological or physical harm to people.

As soon as the top management (e.g. operators, entrepreneurs, companies, approving authorities, building authorities, administrations) of a property has identified such risks to life and limb as part of risk management or similar risk assessments and/or independently became aware of them, this falls within the scope of EN 50726-1.

Read draft and comment

Comment on proposal

Required form fields are indicated by an asterisk (*) character.


Please email further comments to: debbie.stead@bsigroup.com

Follow standard

You are now following this standard. Weekly digest emails will be sent to update you on the following activities:

You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.

Unfollow standard

You have successfully unsubscribed from weekly updates for this standard.

Error