If you have difficulty in submitting comments on draft standards you can use a commenting template and email it to admin.start@bsigroup.com. The commenting template can be found here.

We use cookies to give you the best experience and to help improve our website

Find out what cookies we use and how to disable them

BS ISO 5474-2:2024 Amd 1 NO TITLE

Source:
ISO
Committee:
PEL/69 - Electric vehicles
Categories:
Electric road vehicles
Comment period start date:
Comment period end date:
Number of comments:
0

Comment by:

Scope

This clause applies with the following addition:

This amendment provides requirements for electric vehicles for RPT in grid following mode connected to the distribution network:

— through the vehicle inlet, according to IEC 62196-2, conductively connected to the vehicle power supply circuit; and

— in combination with a Mode 3 EV charging station according to IEC 61851-1 Edition 4 Annex F; and

— with interface protection inside the Mode 3 EV charging station or the upstream electrical installation.

Vehicle requirements for other RPT methods (e.g. grid following mode islanded from the distribution network, grid forming mode islanded from the distribution network) are under consideration.

This amendment shall be read in conjunction with ISO 5474-1 and ISO 5474-2.

Read draft and comment

Comment on proposal

Required form fields are indicated by an asterisk (*) character.


Please email further comments to: debbie.stead@bsigroup.com

Follow standard

You are now following this standard. Weekly digest emails will be sent to update you on the following activities:

You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.

Unfollow standard

You have successfully unsubscribed from weekly updates for this standard.

Error