This document defines the design, safety and operation characteristics of gaseous hydrogen land vehicle (GHLV) refuelling connectors.
GHLV refuelling connectors consist of the following components, as applicable:
— receptacle and protective cap (mounted on vehicle);
— nozzle;
— communication hardware.
This document is applicable to refuelling connectors which have nominal working pressures or hydrogen service levels up to 70 MPa and having flow capacities greater than 120 g/s.
This document is not applicable to refuelling connectors dispensing blends of hydrogen with natural gas.