If you have difficulty in submitting comments on draft standards you can use a commenting template and email it to admin.start@bsigroup.com. The commenting template can be found here.

We use cookies to give you the best experience and to help improve our website

Find out what cookies we use and how to disable them

New work item proposal EN 1991-1-4:2026/prA1 Eurocode 1 — Actions on structures — Part 1-4: Wind Actions

Source:
CEN
Committee:
B/525 - Building and civil engineering structures
Categories:
Information management | Standardization. General rules
Comment period start date:
Comment period end date:

Comment by:

Scope

(1) This document gives rules for the determination of natural wind actions for the structural design of building and civil engineering works for each of the loaded areas under consideration. This includes actions applied to the whole structure or parts of it, as well as wind-exposed elements attached to the structure.

(2) This document is applicable to:

— buildings and other civil engineering works with heights up to 200 m;

— preliminary design stage of buildings and civil engineering works with heights up to 300 m;

— guyed masts, other open lattice structures and chimneys with heights up to 300 m;

— bridges having no span greater than 200 m.

NOTE For wind profiles up to 300 m, see Annex A.

(3) The rules contained in this document allow the evaluation of characteristic wind actions on land-based structures.

(4) This document is applicable to offshore coastal structures.

NOTE Additional or amended provisions can be necessary.

(5) This document does not give guidance on non-synoptic winds (e.g. thunderstorms, downbursts, microbursts, tornadoes, etc.), mixed wind climates, nor does it give guidance on how to account for local effects (e.g. thermal effects, funnelling, strong arctic thermal surface inversion, etc.).

(6) This document addresses simplified procedures for dynamic effects, mostly based on the assumption of a dominant single-mode response (see Annex E, Annex F and Annex G). General criteria for performing a full dynamic analysis under aerodynamic excitation are not treated in this document.

(7) Wind pressure effects of passing vehicles are outside the scope of this document.

NOTE See EN 1991 2 for wind effects from passing trains.

(8) This document also provides guidance on wind tunnel testing and numerical modelling which can be needed or desirable when the shape or structural behaviour are unusual or do not strictly fall within the rules of the document, or in cases of unusual orography or other surroundings.

Purpose

This amendment intends to ensure the consistency between the different Eurocodes and within EN 1991 (all parts), as well as to introduce editorial and technical corrections identified during the FV stage of EN 1991-1-4.

Comment on proposal

Required form fields are indicated by an asterisk (*) character.


Please email further comments to: debbie.stead@bsigroup.com

Follow standard

You are now following this standard. Weekly digest emails will be sent to update you on the following activities:

You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.

Unfollow standard

You have successfully unsubscribed from weekly updates for this standard.