If you have difficulty in submitting comments on draft standards you can use a commenting template and email it to admin.start@bsigroup.com. The commenting template can be found here.
(1) This document deals with the design of steel-concrete composite (SC) structures comprising either:
— two steel plates with shear stud connectors connected by a grid of tie bars and having structural concrete between the plates (referred to as DSC), typically used for walls; or
— a steel plate with shear stud connectors and T stiffeners welded to the plate (referred to as SSC), typically used for floors.
(2) This document gives basic rules for design, design for the construction stage and design for the accidental situation of fire exposure.
1.2 Assumptions
(1) The assumptions of EN 1990 apply to this document.
The purpose of this WI is to create a new version of TS 1994-1-101:2025 with the following changes:
• Correction to two equations
• Improvement to some figures
• Changes to achieve full alignment with Generation 2 Eurocodes
• Editorial modifications for greater ease of use and better clarity
Required form fields are indicated by an asterisk (*) character.
You are now following this standard. Weekly digest emails will be sent to update you on the following activities:
You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.
You have successfully unsubscribed from weekly updates for this standard.
Comment by: