New Work Item Proposal - prEN 50367 Railway applications - Fixed installations and rolling stock - Criteria to achieve technical compatibility between pantographs and overhead contact line

Source:
CENELEC
Committee:
GEL/9/0 - Railway electrotechnical applications
Categories:
Information management | Standardization. General rules
Comment period start date:
Comment period end date:

Comment by:

Scope

This document specifies requirements for the technical compatibility between pantographs and overhead contact lines, to achieve free access to the lines of the European railway network. NOTE These requirements are defined for a limited number of pantograph types conforming to the requirements in 5.3, together with the geometry and characteristics of compatible overhead contact lines.

Purpose

Necessary revision according: - French proposal to change A.3 - Discussion „current at standstill“ – new experiences (AT, DE) - EC Mandat especially: (see Annex of DA): • Standard listed in point 170 of Table 2 of Annex I • “The standard shall describe the technical requirements to ensure that essential requirements established in points 1.4.1, 1.5,2.2.2, 2.2.3 of Annex III to Directive (EU) 2016/797 are complied with. • The standard shall define harmonized parameters and their corresponding assessment methods for the design of the OCL and the pantograph distribution in case of multiple pantograph operation (more than 2). • The standard shall consider the results of the task force from the European Union Agency for Railways TF169-170 and the further studies from the members. • As the standard is directly referenced in both Commission Regulation (EU) 1302/2014 and Commission Regulation (EU) 1301/2014 for the standard pertinent clauses, its Annex ZZ shall be deleted.”

Comment on proposal

Required form fields are indicated by an asterisk (*) character.


Please email further comments to: debbie.stead@bsigroup.com

Follow standard

You are now following this standard. Weekly digest emails will be sent to update you on the following activities:

You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.

Unfollow standard

You have successfully unsubscribed from weekly updates for this standard.

Error