PNW 65C-1365 ED1: Industrial networks – Fieldbus specifications – Part 2-100: Physical layer specification and service definition – Type 100 elements

Source:
IEC
Committee:
GEL/65/3 - Industrial Networks
Categories:
Information management | Standardization. General rules
Comment period start date:
Comment period end date:

Comment by:

Scope

This document is applicable to process automation equipment using a 10BASE-T1L and 100BASE-T1L compliant Physical Layer (PHY). Ethernet-APL intrinsically safe profiles with different predefined entity or limitation parameters (for example voltage, current, power, capacitance, inductance, cable length) simplify the examination of the interconnection of different Ethernet-APL ports. Furthermore, this document is also applicable to factory and building automation equipment using a 10BASE-T1L and 100BASE-T1L compliant, and Power over Data Lines (PoDL) compliant Physical Layer (PHY) for non-intrinsically safe Ethernet installations.

NOTE In this document, the term single pair Ethernet (SPE) is used for PoDL compliant PHY.

 The following technical features are part of this document:

• topology with trunk/spur installation capability;

• 2-wire technology (full-duplex communication data rate of 10 Mbit/s and 100 Mbit/s);

• long distance (refers to cable lengths of several hundred meters, with spans up to 1 000 m);

• intrinsic safety (installation of Ethernet-capable field devices in hazardous areas);

• power supply to field devices over the same 2-wire cable used for data communication;

• Non-intrinsically safe Ethernet installation in factory, process and building automation.

Purpose

New work item proposal 

Comment on proposal

Required form fields are indicated by an asterisk (*) character.


Please email further comments to: debbie.stead@bsigroup.com

Follow standard

You are now following this standard. Weekly digest emails will be sent to update you on the following activities:

You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.

Unfollow standard

You have successfully unsubscribed from weekly updates for this standard.

Error