Please note, we are experiencing intermittent issues on the platform which we are investigating. You may experience issues with submitting comments. If you do encounter issues, please resubmit your comment. Please accept our apologies for any inconvenience caused

We use cookies to give you the best experience and to help improve our website

Find out what cookies we use and how to disable them

New Work Item Proposal - Revision of EN 15384-2

Source:
CEN
Committee:
PKW/0 - Packaging
Categories:
Information management | Standardization. General rules
Comment period start date:
Comment period end date:

Comment by:

Scope

Editorial changes have been made to the Scope given in EN 15384-2:2017; no technical changes have been made.

This document describes the copper sulphate test method for detecting the electrolyte conductivity of internally coated cylindrical or conical aluminium tubes.

It is applicable to aluminium tubes that are used for the packing of pharmaceutical, cosmetic, hygiene, food or other household products.

The internal coating is used as a barrier between the aluminium and the product. The electrolyte conductivity of the internal coating is only one criterion for evaluating the quality of the internal coating of an aluminium tube. It does not give any information on the quantity or size of any pores or uncoated areas nor the possible reactions between the aluminium tube and the product. The electrolyte conductivity is not designed to be used as the sole criterion for quality evaluation of the internal coating, but is designed to be used in conjunction with other parameters, e.g. film thickness, acetone and/or ammonia resistance and the results of enhanced stability studies.

Purpose

With regard to the scope, the standard is extended to cylindrical and conical aluminium tubes. In addition, the end-use markets of aluminium tubes are more generally defined.

For conical tubes the defined distance between the tube’s end and the electrolyte should be extended to at least 15 mm.

It should be clarified that the tolerances given in Table 2 are only valid for standard tubes and not for tubes with additional treatment such as sterilization.

Reference to ISO 2859 or Defect Evaluation List of Editio Cantor in the test report under the item “number of tested tubes”

Comment on proposal

Required form fields are indicated by an asterisk (*) character.


Please email further comments to: debbie.stead@bsigroup.com

Follow standard

You are now following this standard. Weekly digest emails will be sent to update you on the following activities:

You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.

Unfollow standard

You have successfully unsubscribed from weekly updates for this standard.

Error