Find out what cookies we use and how to disable themThis document specifies design requirements for non-powered access installed on cranes.
NOTE 1 For other type of access, a requirement for information to be supplied is specified.
Slidable, retractable means of access are excluded from the scope, except movable hoop guards.
This document covers means of access to control stations and all access required for maintenance, certain erection and dismantling operations.
For those cranes which are intended to be erected and dismantled frequently to change their places of work, specific requirements for the access needed during these operations are not covered by this document and should be given in the appropriate European Standards for specific crane types.
Lighting of means of access is not covered by this document and should be given in the appropriate European Standards for specific crane types.
NOTE 2 Specific requirements for access on particular types of cranes are given in the appropriate European Standard for the particular crane type.
The requirements given in this document do not take into account the safety distances related to:
— guarding against hazard from moving parts;
— relative movement between crane and adjacent structure or the ground/floor;
— hazardous surface temperature;
— electrical equipment.
The significant hazards covered by this document are identified in Clause 4.
This document is not applicable to cranes manufactured before the date of its publication.
The standard needs an update regarding standard references, list of hazards, adopting of the valid CEN drafting rules, updating Annex ZA for Machinery Regulation (EU) 2023/1230. The scope and primary technical content will be kept as it is.
Note: in case the WI is based on documents from other organizations than ISO/IEC, please specify it here
You are now following this standard. Weekly digest emails will be sent to update you on the following activities:
You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.
You have successfully unsubscribed from weekly updates for this standard.
Comment on proposal
Required form fields are indicated by an asterisk (*) character.