We use cookies to give you the best experience and to help improve our website
Find out what cookies we use and how to disable themThis standard specifies the definition and requirements for the interoperability and safety of magnetic field dynamic wireless power transfer(D-WPT) for railways. This standard specify the general requirements of D-WPT which applies to the railway systems in general.
This standard specifies the inter-operable conditions of dynamic wireless power transfer for railways. Interoperability needs to be supported when the manufacturer of primary device is different from the manufacturer of secondary device. Physical interface and efficiency requirements is described.
Also, it specifies the safety requirements of dynamic wireless power transfer for railways. Safety requirements include electrical safety and electro-magnetic safety. Electro-magnetic safety includes electro-magnetic field(EMF) safety with human bodies and electro-magnetic interference(EMI) to devices.
As the testbed construction of dynamic wireless power transfer for railways including light rail transit is increasing, the necessity of standard for dynamic wireless power transfer for railways has been addressed. Dynamic wireless power transfer for railways can solve the problems of catenary system and pantograph in railways such as the friction between catenary and pantograph, the large size of tunnel due to catenary. Regarding the cost comparison between dynamic wireless power transfer and catenary systems, it has been reported that there would be 20%~40% cost reduction at system level by using dynamic wireless power transfer. Dynamic wireless power transfer for railways would improve the landscape of urban city by removing the power line of catenary system. Also, D-WPT expands the operating range of wireless rolling stock. This standard specifies the inter-operable conditions and the safety of dynamic wireless power transfer for railways. This standard will reduce the cost of system construction and speed up the commercialization of dynamic wireless power transfer for railways.
You are now following this standard. Weekly digest emails will be sent to update you on the following activities:
You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.
You have successfully unsubscribed from weekly updates for this standard.
Comment on proposal