CEN/TC 264 N 3089, Revision of EN 15267-4 2017 Air quality — Assessment of air quality monitoring equipment — Part 4: Performance criteria and test procedures for portable automated measuring systems for periodic measurements of emissions from stationary sources

Scope

This document specifies the general performance criteria and test procedures for the performance test of portable automated measuring systems (P-AMS) used for periodic measurements of stationary source emissions. It applies to the performance test of PAMS based on measurement techniques specified by the standard reference method (SRM) or an alternative method (AM). The performance test is based on the general performance criteria and test procedures specified in this document and on the specific requirements specified for the SRM or AM. This includes testing of the applicability and correct implementation of the QA/QC procedures specified for the SRM or AM.

This document supports the requirements of particular EU Directives.

Purpose

The assessment of air quality monitoring equipment (AQME) supports the requirements of certain Directives of the European Union (EU), which require, either directly or indirectly, that this equipment complies with performance criteria, maximum permissible measurement uncertainties and test requirements. These Directives include the Directive 2010/75/EU on industrial emissions (IED), Directive (EU) 2015/2193 on medium combustion plants and the Directive 2008/50/EC on ambient air quality and cleaner air for Europe.

The assessment of AQME consists of the following sequential stages:

a) performance testing;

b) initial assessment of the manufacturer’s quality management system (QMS);

c) certification;

d) surveillance for the manufacturing process.

The EN 15267 series of European Standards will cover the following:

— Part 1: General principles of certification

— Part 2: Initial assessment of the manufacturer’s quality management system and post certification surveillance for the manufacturing process

— Part 3: Performance criteria and test procedures for stationary automated measuring systems for continuous monitoring of emissions from stationary sources

— Part 4: Performance criteria and test procedures for portable automated measuring systems for periodic measurements of emissions from stationary sources

Part 4 specifies the performance criteria and test procedures for performance testing of portable automated measuring systems (PAMS) used for periodic measurements of stationary source emissions. Testing applies to complete measuring systems.

Comment on proposal

Required form fields are indicated by an asterisk (*) character.


Please email further comments to: debbie.stead@bsigroup.com

Follow standard

You are now following this standard. Weekly digest emails will be sent to update you on the following activities:

You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.

Unfollow standard

You have successfully unsubscribed from weekly updates for this standard.

Error