We use cookies to give you the best experience and to help improve our website
Find out what cookies we use and how to disable themThis European Standard specifies a continuous measurement method for the determination of the concentration of sulphur dioxide present in ambient air based on the ultraviolet fluorescence measuring principle. This standard describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate ultraviolet fluorescence analyser by means of type approval tests. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use.
The method is applicable to the determination of the mass concentration of sulphur dioxide present in ambient air up to 1000 μg/m3. This concentration range represents the certification range for SO2 for the type approval test.
NOTE 1 Other ranges may be used depending on the levels present in ambient air.
NOTE 2 When the standard is used for other purposes than for measurements required by Directive 2008/50/EC, the ranges and uncertainty requirements may not apply.
The method covers the determination of ambient air concentrations of sulphur dioxide in zones classified as rural areas, urban-background areas and traffic-orientated locations and locations influenced by industrial sources.
The results are expressed in μg/m3 (at 20 °C and 101,3 kPa).
NOTE 3 1 000 μg/m3 of SO2 corresponds to 376 nmol/mol of SO2.
This standard contains information for different groups of users.
Clauses 5 to 7 and Annexes C and D contain general information about the principles of sulphur dioxide measurement by ultraviolet fluorescence analyser and sampling equipment.
Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type-approval testing of sulphur dioxide analysers.
These sections contain information about:
− Type-approval test conditions, test procedures and test requirements;
− Analyser performance requirements; − Evaluation of the type-approval test results;
− Evaluation of the uncertainty of the measurement results of the sulphur dioxide analyser based on the type approval test results.
Clauses 9 to 11 and Annexes F and G are directed towards monitoring networks performing the practical measurements of sulphur dioxide in ambient air.
These sections contain information about:
− Initial installation of the analyser in the monitoring network and acceptance testing;
− Ongoing quality assurance/quality control;
− Calculation and reporting of measurement results;
− Evaluation of the uncertainty of measurement results under practical monitoring conditions.
• 8.4 "Procedures for determination of the performance characteristics during the laboratory test", 8.5 "Determination of the performance characteristics during the field test", and 8.6 "Checks": equations need to be reviewed
• 9.6.1.2 "Performance of zero and span checks": the first equation is wrong, the absolute needs to be removed
• References to type approval should be revised
• References to EN ISO/IEC17025 should be revised
• Reference to ISO 19229 "Purity analysis" should be added
• Calculation of measurement uncertainties in the annexes need to be reviewed
You are now following this standard. Weekly digest emails will be sent to update you on the following activities:
You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.
You have successfully unsubscribed from weekly updates for this standard.
Comment on proposal
Required form fields are indicated by an asterisk (*) character.