If you have difficulty in submitting comments on draft standards you can use a commenting template and email it to admin.start@bsigroup.com. The commenting template can be found here.
The method described in this document is used to determine combined wheel-rail roughness and track decay rates from rail vibration during the pass-by of a train. By combining sound pressure measurement from the same pass-by, a vibro-acoustic transfer function for rolling noise is determined.
This document describes a method for the following purposes:
— to measure track decay rates under operational conditions;
— to characterize the effectiveness of noise control measures in terms of combined roughness, transfer function and track decay rate;
— to compare the combined roughness before and after noise control measures are implemented (thereby quantifying the effect of any change in wheel or rail roughness);
— to monitor wheel roughness during a pass-by, either of whole trains or parts of trains;
— to separate rolling noise from other sources;
— to assess a threshold for the rail roughness, by measuring multiple pass-bys;
— to obtain combined roughness and transfer functions for input to environmental noise calculations.
The method is not for approval of sections of reference track in terms of acoustic rail roughness and track decay rates, which are covered by EN 15610:2019+A1:2025 [9] and [10], respectively.
EN 15461:2008+A1:2010 The method is applicable to trains on conventional tracks, i.e. normal ballasted tracks with wooden or concrete sleepers and on slab tracks.
Annex A and Formula (A.1) give guidance on the calculation of the A2 factor, if the method is applied to:
— non-standard wheel types such as small wheels, resilient tram wheels;
— non-standard track types such as embedded rail or grooved rail.
Required form fields are indicated by an asterisk (*) character.
You are now following this standard. Weekly digest emails will be sent to update you on the following activities:
You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.
You have successfully unsubscribed from weekly updates for this standard.
Comment by: