If you have difficulty in submitting comments on draft standards you can use a commenting template and email it to admin.start@bsigroup.com. The commenting template can be found here.
This document specifies design methods for combination of actions and spans for factory made double skin metal faced insulating sandwich panels (hereafter sandwich panels). The sandwich panels are for use in self-supporting and structural applications in roofs, in external and internal walls (including partitions) and in ceilings in buildings as well as those in cold store applications.
This document covers uniformly distributed loads, line loads perpendicular to the span over the full width of the panel and thermal gradients, it gives no information about normal forced axially loaded sandwich panels, torsional loaded sandwich panels or sandwich panels as a part of a diaphragm.