If you have difficulty in submitting comments on draft standards you can use a commenting template and email it to admin.start@bsigroup.com. The commenting template can be found here.
This part of IEC 61810, with functional and safety aspects, applies to electrical relays (non-specified time all-or-nothing relays) with high capability requirements like breaking or short circuit capabilities and similar for incorporation into low-voltage equipment. These relays may have a specific design to extinguish the electric arc between contacts (e.g. by magnetic blow-out), or use an insulation coordination not covered by IEC 61810-1:xxxx (e.g. by gas filled contact chambers), or require safety assessments not covered by IEC 61810-1:xxxx (e.g. for higher loads).
It defines additional requirements for high-capacity relays with generic performance intended for use in applications in smart grids, electric vehicles and other applications where, for example, battery charge/discharge switching is used, such as:
– electrical energy storage (EES) systems,
– solar photovoltaic energy systems,
– electric road vehicles (EV) and electric industrial trucks,
– power electronic systems and equipment,
– secondary cells and batteries,
– road vehicles.
Compliance with the requirements of this standard is verified by the type tests indicated.