If you have difficulty in submitting comments on draft standards you can use a commenting template and email it to admin.start@bsigroup.com. The commenting template can be found here.
This document specifies the:
— field of application:
— The dimensional, the physicochemical, the design, the hydraulic, the mechanical and the acoustic characteristics of non-controllable backflow preventer with different pressure zones, family C, type A, nominal sizes DN 6 to DN 25, nominal pressure PN 10.
It is applicable to:
— Family C, type A, class “a” for general use: devices of class “a” can be capable of working:
— at any pressure up to 1 MPa (10 bar);
— with any pressure variation up to 1 MPa (10 bar);
— at a supply temperature limit of 65 °C and 90 °C for 1 h;
— Family C, type A, class “b” for specific use: devices of class “b” shall be capable of working:
— at any downstream pressure up to 0,3 MPa (3 bar);
— with any downstream pressure variation up to 0,3 MPa (3 bar); at a supply temperature limit of 65 °C and 90 °C for 1 h;
Class “b” devices can capable of operating: at any downstream pressure up to 300 kPa (3 bar), with any downstream pressure variation up to 300 kPa (3 bar) at a supply temperature limit of 65 °C and 90 °C for 1 h. Class “b” devices with specific hydraulic and non-acoustic requirements and are intended to equip filling devices physically integrated into a single-function (heating) or dual-function (heating and domestic hot water) boiler.
It specifies also:
— test methods and requirements for verifying these characteristics;
— marking;
— presentation and the delivery
Required form fields are indicated by an asterisk (*) character.
You are now following this standard. Weekly digest emails will be sent to update you on the following activities:
You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.
You have successfully unsubscribed from weekly updates for this standard.
Comment by: