BS EN ISO 19277-1 Oil and gas industries including lower carbon energy— Qualification testing and acceptance criteria for protective coating systems under insulation. Part 1: Liquid applied coatings

Source:
ISO
Committee:
PSE/17 - Oil and gas industries including lower carbon energy
Categories:
Petroleum products and natural gas handling equipment | Paints and varnishes
Comment period start date:
Comment period end date:
Number of comments:
0

Comment by:

Scope

This document describes various corrosion under insulation (CUI) environments in refineries and other related industries and environments and establishes CUI environmental categories including operating temperature ranges from −45 °C to 204 °C for topside and aboveground service only. This document specifies both established and other test methods for the assessment of coatings used for prevention of CUI for each given environment. This document also provides acceptance criteria for each CUI environment.

NOTE The test results and acceptance criteria can be considered an aid in the selection of suitable coating systems. For service or peak temperatures over 204 °C testing acceptance criteria can be agreed between interested parties. Additional or other test and acceptance measures are possible but require particular agreement between the interested parties.

This document covers spray-applied coatings applied on new carbon steel for use in CUI service. The coatings can be used for new built structures and for existing structures where maintenance of the coating is needed. This document does not cover testing of sacrificial coatings, such as inorganic zinc, as these coatings can be consumed quickly in wet environments. Developing accelerated corrosion testing for what can be continuous wet service with sacrificial coatings is beyond the scope of this document.

“Non-through porosity” thermal spray aluminium coatings with greater than 250 µm dry film thickness can be tested and qualified in accordance with this document. This document does not cover tape and sheet applied products for use in preventing CUI.

This document does not deal with other aspects of coating degradation, such as those caused by abrasion, erosion, ultraviolet degradation or other methods that can exist given specific environment and construction methods.

Read draft and comment

Comment on proposal

Required form fields are indicated by an asterisk (*) character.


Please email further comments to: debbie.stead@bsigroup.com

Follow standard

You are now following this standard. Weekly digest emails will be sent to update you on the following activities:

You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.

Unfollow standard

You have successfully unsubscribed from weekly updates for this standard.

Error