If you have difficulty in submitting comments on draft standards you can use a commenting template and email it to admin.start@bsigroup.com. The commenting template can be found here.
This document describes a method for evaluating the carbonation resistance of concrete using test conditions that accelerate carbonation. After a defined period of curing and a period of preconditioning, the test is carried out under controlled exposure conditions using an increased level of carbon dioxide.
NOTE The test performed under reference conditions takes a minimum of 112 days comprising a minimum age of the specimen prior to curing under water of 28 days, a minimum preconditioning period of 14 days and an exposure period to increased carbon dioxide level of 70 days.
This procedure is not a method for the determination of carbonation depths in existing concrete structures.