BS EN 12681-2 EN 12681-2 Founding. Radiographic testing. Part 2: Techniques with digital detectors

Source:
CEN
Committee:
ISE/111 - Steel Castings and Forgings
Categories:
Metal testing. Non-destructive
Comment period start date:
Comment period end date:
Number of comments:
0

Comment by:

Scope

This document gives specific procedures for industrial X-ray and gamma radiography for discontinuity detection purposes, using NDT (non-destructive testing) digital X-ray image detectors. This part of the EN 12681 series specifies the requirements for digital radiographic testing by either computed radiography (CR) or radiography with digital detector arrays (DDA) of castings.

Digital detectors provide a digital grey value image which can be viewed and evaluated using a computer.

NOTE This part of the EN 12681 series complies with EN 14784-2 for CR. Some clauses and annexes are taken from EN ISO 17636‑2.

This part of the EN 12681 series specifies the recommended procedure for detector selection and radiographic practice. Selection of computer, software, monitor, printer and viewing conditions are important but are not the main focus of this document. The procedure specified in this document provides the minimum requirements for radiographic practice which permit exposure and acquisition of digital images with equivalent sensitivity for detection of imperfections as film radiography, as specified in EN 12681‑1.

This document does not consider radiographic or radioscopic fitness for purpose testing as applied for specific castings based on manufacturer’s internal requirements and procedures.

The requirements on image quality in testing class A and B testing of Annex A consider the good workmanship quality for general casting applications as also required in EN 12681‑1 for film radiography.

The testing classes AA and BA reflect the quality requirements of current automated and semi-automated radiographic testing systems with DDAs and computer- or operator-based image evaluation, and mini- or micro-focus tubes (spot size ≤ 1 mm) with reduced requirements to the unsharpness, but unchanged requirements to contrast sensitivity as also required in EN 12681‑1 for film radiography.

The specified procedures are applicable to castings produced by any casting process, especially for steels, cast irons, aluminium, cobalt, copper, magnesium, nickel, titanium, zinc and any alloys of them.

This document does not apply to:

— the testing of welded joints (see EN ISO 17636‑2);

— film radiography (see EN 12681‑1);

— real time testing with radioscopy (see EN 13068‑1; radioscopy with image intensifiers).

Read draft and comment

Comment on proposal

Required form fields are indicated by an asterisk (*) character.


Please email further comments to: debbie.stead@bsigroup.com

Follow standard

You are now following this standard. Weekly digest emails will be sent to update you on the following activities:

You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.

Unfollow standard

You have successfully unsubscribed from weekly updates for this standard.

Error