This document specifies methods of measuring the strippability and adherence of the insulation to a conductor of a finished cable.
When a particular method is not specified in the detail product specification, method A is the default test method.
Method B is suitable for wires insulated with materials showing a low adhesion to the conductor due to the poor repeatability of the test method A with this type of wires.
It is intended to be used together with EN 3475‑100.