BS IEC 62862-3-7 Ed.1.0 BS EN 62862-3-7 Ed.1.0 Solar thermal electric plants. Part 3-7: Criteria for design, installation and performance verification of flexible pipe connectors in parabolic trough collector technology

Source:
IEC
Committee:
RHE/25 - Solar Heating
Categories:
Solar energy engineering
Comment period start date:
Comment period end date:
Number of comments:
0

Comment by:

Scope

This standard specifies the minimum requirements for the design and verification of the performance of flexible pipe connectors in solar thermal power plants with parabolic trough collector technology. It also includes guidelines or aspects to be considered for the installation of these components in the solar field. In particular, the following are included:

–        Manufacturer's design requirements, instructions and tests

–        Installation requirements for flexible pipe connectors

–        Pressure drop test

–        Testing of stresses and longitudinal displacements and rotations

–        Thermal cycling test

–        Life cycle testing

–        Maximum torque test

–        Leakage verification testFlexible pipe connectors can be:

–        Rotary joints

–        Flexible hoses

–        Joints composed of flexible hoses and rotary joints

Other types and applications not explicitly mentioned in this document are outside the scope of this standard.

Read draft and comment

Comment on proposal

Required form fields are indicated by an asterisk (*) character.


Please email further comments to: debbie.stead@bsigroup.com

Follow standard

You are now following this standard. Weekly digest emails will be sent to update you on the following activities:

You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.

Unfollow standard

You have successfully unsubscribed from weekly updates for this standard.

Error