We use cookies to give you the best experience and to help improve our website

Find out what cookies we use and how to disable them

BS EN IEC 61250 ED2 BS EN 61250 ED2 Nuclear reactors - Instrumentation and control systems important for safety - Detection of leakage in coolant systems

Source:
IEC
Committee:
NCE/8 - Instrumentation, Control & Electrical Systems of Nuclear Facilities
Categories:
Nuclear power plants. Safety
Comment period start date:
Comment period end date:
Number of comments:
0

Comment by:

Scope

This document establishes the requirements for instrumentation needed to detect leakage from reactor coolant systems of all types of light water nuclear reactors. Methods of leakage detection are described and characteristics of different methods of detection and of differentiating between allowable and abnormal leakages are given.

The sensitivity of systems required to ensure early detection of developing leaks and to give warning of possible leak-before-break situations is considered, and recommendations are given to reduce spurious alarms.

Recommendations are given for data display which will allow presentation in a clear and concise manner to enable operators to take appropriate actions to minimize the risk of hazard to plant equipment and to personnel. Requirements are given for recording and logging, as well as for summation of individual signals to detect trends.

The objective of this document is to define the requirements for leakage detection data, for arranging it in a logical manner, and for displaying information to enable the operator to take appropriate action. A secondary objective of this document is to standardize criteria, methods and procedures for assuring the design and operational adequacy of the reactor coolant and associated systems (RCAS) leakage detection systems used in light water cooled nuclear reactors.

Read draft and comment

Comment on proposal

Required form fields are indicated by an asterisk (*) character.


Please email further comments to: debbie.stead@bsigroup.com

Follow standard

You are now following this standard. Weekly digest emails will be sent to update you on the following activities:

You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.

Unfollow standard

You have successfully unsubscribed from weekly updates for this standard.

Error