BS EN 1364-4 EN 1364-4 Fire resistance tests for non-loadbearing elements. Part 4: Curtain walling. Part configuration

Source:
CEN
Committee:
FSH/22/-/7 - Non loadbearing separating elements
Categories:
Fire-resistance. Building materials and elements | Walls. Partitions. Façade
Comment period start date:
Comment period end date:
Number of comments:
0

Comment by:

Scope

This document specifies a method for determining the fire resistance of parts of curtain walling and of the perimeter seal. It examines the fire resistance to internal and external fire exposure of:

— the spandrel panel, i.e. downstand, upstand or a combination thereof;

— the perimeter seal;

— the fixing of the framing system (anchoring) used to attach the curtain walling to the floor element;

— combinations thereof.

NOTE 1 This document does not test fire spread that can be caused through cavities in the test specimen, i.e. inside of the mullions (see note to 9.1.2.3.3).

Results from tests according to this document form the basis for classification of curtain walling type A (see 3.3 for definition).

For curtain walling type B (see 3.4 for definition) results can be used to determine fire resistance of parts of a curtain walling to increase the field of application when previously tested to EN 1364‑3. For intended classification EW and for corner/faceted specimens EN 1364‑3 can be used.

This document does not cover double skin façades, over-cladding systems and ventilated façade systems on external walls. It does not deal with the reaction to fire behaviour of curtain walling.

This document is intended to be read in conjunction with EN 1363‑1 and EN 1363‑2 as well as EN 1364‑3 for curtain walling type B.

As per the type of curtain walling covered by this document, these are the ones included in EN 13119.

NOTE 2 Annex A gives informative guidance on the principles of testing parts of curtain walling and the test method.

NOTE 3 When tests are made to examine single elements (e.g. perimeter seal), those elements are to be installed as part of a curtain walling system.

Read draft and comment

Comment on proposal

Required form fields are indicated by an asterisk (*) character.


Please email further comments to: debbie.stead@bsigroup.com

Follow standard

You are now following this standard. Weekly digest emails will be sent to update you on the following activities:

You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.

Unfollow standard

You have successfully unsubscribed from weekly updates for this standard.

Error