This document specifies a test method for short-term flicker effects of lighting equipment for general lighting purposes, which can be applied for the following purposes:
– measuring the intrinsic performance of all lighting equipment without the application of voltage fluctuations in terms of light output flicker metric ; during this measurement, the lighting equipment is supplied with a stable AC or DC power source;
– measuring the immunity performance of lighting equipment, which is rated for 120 V AC and 230 V AC, 50 Hz and 60 Hz, against (unintentional) voltage fluctuation disturbance on the AC mains in terms of light output flicker metric ; during this test a set of defined voltage fluctuations are supplied with the power source and the immunity of the lighting equipment to the disturbance is determined;
NOTE 1 The principle of the method can be applied for other nominal voltage ratings.
– measuring the compatibility performance of lighting equipment with external light controls without the application of voltage fluctuations in terms of light output flicker metric; during this measurement, the lighting equipment is supplied with a stable power source.
This document is applicable to lighting equipment with the following optical characteristics:
chromaticity coordinates x and y in the range
o 0,270 < x < 0,530 and
o - 2,3172 x2 + 2,3653 x - 0,2199 < y < - 2,3172 x2 + 2,3653 x - 0,1595, and
a luminous flux between 60 and 82,000 lumen, and
a colour rendering index (CRI) > 0.
This document does not apply to assess:
The immunity performance of lighting equipment against intentional voltage fluctuations on the AC mains arising from mains signalling or ripple controls.
NOTE 2 IEC 61000-4-13:2015 provides guidance regarding test levels and frequencies for mains signalling.
Temporal changes in the colour of light (chromatic effects)