Find out what cookies we use and how to disable themThis document specifies a method for the calibration of spherical tanks with radius greater than 1 m by means of external measurements using an electro-optical distance-ranging instrument (EODR) , and for the subsequent compilation of tank capacity tables.
This document applies to spherical tanks built above ground, non-insulated, single-shell and with a radial variation up to 1 %. This method can also apply to spherical tanks built above the deck when the carrying ship is in the dock.
This document does not apply to the calibration of spheroidal tanks.