BS IEC 61196-1-326 ED2 BS EN 61196-1-326 ED2 Coaxial communication cables. Part 1-326: Test methods - Clamps test

Source:
IEC
Committee:
PEL/213 - Cable management
Categories:
Coaxial cables. Waveguides
Number of comments:
0

Scope

This specification specifies the test methods of clamps for laying coaxial communication cable, including mechanical test methods and environmental test methods.

This specification applies to clamps for laying coaxial communication cables, including feeder and radiating cables.

This specification includes the following test methods:

a)      Mechanical test methods:

1)      Clamping force (Clause 5),

2)      Normal tensile force (Clause 6),

3)      Shear force (applicable to spacer clamps) (Clause 7),

4)      Suitability test (Clause 8),

5)      Fastener force test (applicable to feeder clamps) (Clause 9),

6)      High cycle fatigue (applicable to spacer clamps) (Clause 10).

b)      Environmental test methods:

1)      Climatic sequence (Clause 11),

2)      Salt mist (Clause 12),

3)      Solar radiation (applicable to outdoor clamps) (Clause 13),

4)      Cold temperature installation (applicable to spacer clamps) (Clause 14),

5)      Fire-resistance (fireproof clamp) (applicable to spacer clamps) (Clause 15).

Comment on proposal

Required form fields are indicated by an asterisk (*) character.


Please email further comments to: debbie.stead@bsigroup.com

Follow standard

You are now following this standard. Weekly digest emails will be sent to update you on the following activities:

You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.

Unfollow standard

You have successfully unsubscribed from weekly updates for this standard.

Error