BS ISO 16200-1 ISO 16200-1 Workplace air. Sampling and analysis of volatile organic compounds by solvent desorption/gas chromatography. Part 1: Pumped sampling method

Source:
ISO
Committee:
EH/2/2 - Work place atmospheres
Categories:
Workplace atmospheres
Comment period start date:
Comment period end date:
Number of comments:
0

Comment by:

Scope

This part of ISO 16200 gives general guidance for the sampling and analysis of volatile organic compounds (VOCs) in air by solvent desorption/gas chromatography using pumped sampling.

This part of ISO 16200 is applicable to a wide range of VOCs, including hydrocarbons, halogenated hydrocarbons, esters, glycol ethers, ketones and alcohols. A number of sorbents are recommended for the sampling of these VOCs, each sorbent having a different range of applicability. However, activated coconut shell charcoal is frequently used. Very polar compounds may require derivatization; very low boiling compounds may only be partially retained by the sorbents and can only be estimated qualitatively. Semi-volatile compounds should be fully retained by the sorbents, but may only be partially recovered.

The upper limit of the useful range is set by the sorptive capacity of the sorbent used and by the linear dynamic range of the analytical instrumentation used. The lower limit of the useful range depends on the type of detector used, on the noise level of the detector and on blank levels of analyte and/or interfering artefacts on the sorbent tubes or in the desorption solvent. Artefacts are typically sub-nanogram for activated charcoal, but higher levels of aromatic hydrocarbons have been noted in some batches. By applying this part of ISO 16200, the lower limits achieved are typically in the range of 1 µg to 100 µg of a given VOC per sample.

The concentration range for which this part of ISO 16200 is valid for the measurement of airborne vapours of VOCs is dependent on the lower limit and on the volume sampled. For example, for a 10-litre sample of air, the range is approximately 0,1 mg/m3 to 100 mg/m3 individual organic compound. For a 1-litre sample of air, the range is approximately 1 mg/m3 to 1 000 mg/m3 individual organic compound, and pro rata.

Read draft and comment

Comment on proposal

Required form fields are indicated by an asterisk (*) character.


Please email further comments to: admin.start@bsigroup.com

Follow standard

You are now following this standard. Weekly digest emails will be sent to update you on the following activities:

You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.

Unfollow standard

You have successfully unsubscribed from weekly updates for this standard.

Error