We use cookies to give you the best experience and to help improve our website

Find out what cookies we use and how to disable them

BS EN IEC 60079-19 ED 5 BS EN 60079-19 ED 5 Explosive atmospheres. Part 19: Equipment repair, overhaul and reclamation

Source:
IEC
Committee:
EXL/31/3 - Codes of practice
Categories:
Electrical apparatus. Explosive atmospheres
Number of comments:
1

Scope

This part of IEC 60079:

–        gives instructions, principally of a technical nature, on the repair, overhaul, reclamation, and alteration and modification of Ex equipment designed for use in explosive atmospheres;

–        applies to overhaul and repair which mitigates deficiencies identified during operation, inspection and maintenance;

–        applies to manufacturers who overhaul and repair Ex Equipment which has been manufactured by other manufacturers;

–        assumes that good engineering practices are adopted throughout;

–        does not give advice on cable and wiring systems which can require a renewal when the equipment is re-installed; and–     

    –        is not applicable to Type of Protection “m”; and.

–        is not applicable to manufacturers who overhaul and repair equipment which they have manufactured, however they may take  into consideration the requirements of marking and user records for the user’s verification record.

Comment on proposal

Required form fields are indicated by an asterisk (*) character.


Please email further comments to: debbie.stead@bsigroup.com

Follow standard

You are now following this standard. Weekly digest emails will be sent to update you on the following activities:

You can manage your follow preferences from your Account. Please check your mailbox junk folder if you don't receive the weekly email.

Unfollow standard

You have successfully unsubscribed from weekly updates for this standard.

Error