Scope
This document specifies test methods for determination of characteristics for fixing of factory-made double skin metal faced insulating sandwich panels (hereafter referred to as sandwich panels) to substructure and for stabilization of substructure. Sandwich panels are used in elements for both self-supporting and structural applications in roofs, in external and internal walls (including partitions) and in ceilings in buildings as well as those in cold store applications.
NOTE The description of self-supporting sandwich panels is given in prEN 14509-1 and for structural sandwich panels in FprEN 14509-2.